HBS860H Closed Loop Stepper Driver 0.4-8.2A AC18-80V
The HBS860H is a closed loop hybrid servo drive for 57/60 and 86 series stepper motors. It takes AC 18-80 V or DC 24-110 V, delivers 0.4 to 8.2 A per phase, and closes the loop on the motor encoder instead of trusting the pulse count.
Overview
An open loop stepper loses steps when the load wins. On a machine that stalls in a heavy cut, that shows up as a lost position that nothing detects until the part is measured. The HBS860H reads the encoder on the motor and corrects the current to hold the commanded position, and it raises a position deviation alarm when the error exceeds its limit instead of silently carrying on.
It is built around a 32 bit motor control MCU running vector servo control, which is what lets the same drive hold position at standstill and still respond to pulses at 200 Kpps. Both Position and Speed control modes are available.
Specifications
| Model | HBS860H hybrid servo drive |
| Motor series | 57/60 and 86 series hybrid stepper motors |
| Power input | AC 18-80 V or DC 24-110 V |
| Output current | 0.4 - 8.2 A per phase |
| Control method | Position or Speed |
| Max response frequency | 200 Kpps |
| Microstep | 15 settings, up to 51200 ppr |
| Electronic gear ratio | Supported |
| Signal I/O | Opto-isolated, 5-24 V |
| Protection | Over heat, over current, over voltage, over speed, position deviation |
| Dimensions | 150 x 97.5 x 52.7 mm |
| Net weight | 650 g |
Wiring
Motor and power share the six-pin terminal: A+ A- B+ B- for the two phases, then AC/V+ and AC/V- for the supply. Wire colour order on our motors is white, green, blue, black for A+ A- B+ B-; if the motor turns the wrong way, swap A+ with A- or B+ with B- rather than reversing the supply.
The encoder has its own six-pin terminal: EB+ EB- EA+ EA- VCC EGND, with 5 V supplied by the drive. Control signals are PUL+ PUL- DIR+ DIR- ENA+ ENA- plus Pend+ Pend- for in-position output and ALM+ ALM- for alarm output. Inputs accept 5-24 V, so a 24 V controller can drive them directly. When the ALM port is used to release a brake, SW8 has to be set to ON.
The enclosure carries a fan that starts above 40 degrees C. Above 70 degrees C the drive cuts output current and stops until it falls back to 40 degrees C, so a cabinet with no airflow will show up as a drive that stops mid program rather than as an obvious overheat fault.
What it replaces
The natural upgrade path is an open loop driver on the same machine: same mounting footprint class, same pulse and direction signals, same 86 frame motor. If you are already running a plain 86 stepper driver and losing position on heavy cuts, this is a drop-in change at the wiring level, plus the encoder cable that the closed loop needs.
It is not a servo replacement for high acceleration work. It is a stepper drive that stops losing steps.
FAQ
Does it need an encoder?
Yes. Closed loop means the drive reads the motor encoder; without the encoder cable it will not run in closed loop mode.
What supply should I use?
AC 18-80 V or DC 24-110 V. On an 86 frame motor at high current, run nearer the top of that band so the drive has voltage headroom at speed.
Can it drive a 57 motor as well as an 86?
Yes, 57/60 and 86 series are both supported. Set the current with the DIP switches to the motor's rated phase current, not to the drive maximum.
What microstep should I set?
Enough resolution for the axis, no more. 15 settings are available up to 51200 ppr; very high settings cost pulse frequency headroom without improving mechanical accuracy.
Related products
NEMA 34 closed loop stepper · HBS57 stepper driver · DM430S two phase stepper driver · Stepper motor bracket · Ask for a quotation
Hot Tags: hbs860h,closed loop stepper driver,hybrid servo drive,86 stepper driver,stepper driver 8.2a, 2 axis servo motor, 20 kg servo motor, coreless servo motor, motor and driver for snow blowers, servo motor for drone, servomotor 230v
You Might Also Like